| Input type, RTD | 100, 200, 500, 1000 Ω platinum, alpha=385, 100, 200, 500, 1000 Ω platinum, alpha=3916, 120 Ω nickel, alpha=672, 100, 120, 200, 500 Ω nickel, alpha=618, 10 Ω copper 427 |
| Input type, thermocouple | B, C, D, E, J, K, L (TXK/XK), N, R, S, T |
| Output Signal | Analog |
| Number Of Channels | 4 Channel |
| Real-time channel sampling | True |
| Common mode voltage | ±10V (Current mode and 3-wire RTD mode), ±2V (Voltage mode) |
| Input range, voltage | ±10V @ 0...10V, 0...5V |
| Input, voltage | True |
| Isolation voltage | 250V (continuous), basic insulation type, 50V Functional isolation between SA power and input ports, No isolation between individual input ports |
| Output, voltage | False |
| Overvoltage protection, max | Voltage, current, RTD, and thermocouple/mV modes: ±30V DC |
| Resolution, voltage | 16 bit at 10 Hz notch filter: ±10.5V: <320 µV/count (15 bit plus sign bipolar), 0...10.5V: <160 µV/count (16 bit unipolar), 0...5.25V: <80 µ/V count (16 bit unipolar) |
| Voltage variation | 10 ms interruption on MOD power port |
| Input range, current | 0...20mA @ 4....20mA |
| Input, current | True |
| Output, current | False |